When you compare acoustic panels, the first number you see is usually the NRC. Here is what it means, how to read it, and how to get more from the same panels.
What NRC measures
NRC stands for Noise Reduction Coefficient. It is a single number between 0 and 1 that summarises how much sound a material absorbs. It is the average of the absorption measured at four frequencies that matter most for speech: 250, 500, 1000 and 2000 Hz.
- NRC 0: the surface reflects all the sound that reaches it, like glass or tile.
- NRC 1: the surface absorbs all of it.
What NRC 0.40 means
An NRC of 0.40 means the panel absorbs about 40% of the sound energy that reaches it, on average across speech frequencies, and reflects about 60% back into the room. Compared with bare plaster or glass, which absorb only a few percent, that is a large change: each reflection loses much of its energy, so echo fades faster and voices are clearer.
Lubad felt, by thickness
- 9 mm: NRC 0.30
- 12 mm: NRC 0.40
- 24 mm (one solid board): NRC 0.60
Values measured to EN ISO 354, with the panel on a hard surface and no air gap. Colour does not change the result: absorption depends on thickness and density, and every Lubad colour is the same material.
Want more absorption? Add an air gap
Felt absorbs sound by slowing down the movement of air in its fibres. Right against a wall, the air barely moves, especially at lower frequencies. Mounting the panels a few centimetres off the wall puts the felt where the air moves more, so it absorbs more.
- 12 mm on the wall: NRC 0.40 (tested)
- 12 mm with an air gap: more absorption, especially at lower frequencies (test requested)
- 24 mm with a 50 mm air gap: NRC 0.80 (manufacturer data)
We have requested a laboratory test of 12 mm felt with an air gap and will publish the result when it arrives. Real results depend on the room and the installation.
NRC is not sound insulation
Acoustic felt reduces echo inside a room. It does not stop noise travelling between rooms; that needs sound insulation in the walls, doors and ceilings, measured with different ratings (STC or Rw). Many projects need both, in different places. Ask us if you are not sure which you need.
How much to use
As a starting point, treat 15 to 20% of the hard surfaces in living spaces, about 30% in meeting rooms, restaurants and rooms with obvious echo, and about 50% in studios. Our calculating guide walks through it.
References
- EN ISO 354: Acoustics. Measurement of sound absorption in a reverberation room.
- ASTM C423: definition of the Noise Reduction Coefficient (average of 250, 500, 1000 and 2000 Hz).
- Cox, T. J. and D’Antonio, P., Acoustic Absorbers and Diffusers: Theory, Design and Application, 3rd ed., CRC Press, 2016: chapter on porous absorbers and the effect of an air gap.